(144c) Identifying the Processing Space of Continuous Granulation: A Case Study of Extended Release Tablets | AIChE

(144c) Identifying the Processing Space of Continuous Granulation: A Case Study of Extended Release Tablets

Authors 

Zidan, A. - Presenter, U.S. Food and Drug Administration
While continuous manufacturing (CM) has been employed for directly compressible tablets, the continuous wet granulation has also been used as an alternative in continuous tableting lines. To date, no matrix-based extended release tablets manufactured by a CM technology has been approved. Compared to batch granulation, continuous twin screw granulation exerts higher shear to produce denser granules with broader size distribution within very short time (seconds). Changing the screw configuration, process, and formulation parameters can alter the physical properties of the granules, e.g., shape, flow, compressibility, density, size distribution, etc. In twin screw granulation, complex interactions among these parameters manage the granule properties. This study aimed at identifying the critical material attributes and process parameters and their interactions to be controlled for switching a batch process to a CM granulation process.

Using batch high shear granulation, we evaluated the formulation and process parameters that can produce metoprolol succinate extended release tablets. These formulation and process parameters were successfully transferred to continuous twin screw granulation to produce the same dissolution properties of the finished product. The effects of the screw configuration parameters on the characteristics of the granules were further investigated. The interaction between the processing, e.g., liquid to solid ratio, screw speed, barrel fill volume, etc., and the significant screw parameters was studies to unveil the processing space and to identify the failure modes.

Similar granule quality attributes were obtained for most of the formulations; although, the conditioned bulk density and compressibility of the granules determined the dissolution properties of the tablets. The number of kneading and sizing elements had the most significant impact on granule characteristics. The effects of the staggering angle and distance between the kneading zone of the screws were negligible.

This presentation will then highlight the processing space of screw granulation to produce extended release tablets. Some of the failure modes will be discussed along with the feasibility of implementing PAT tools to monitor the granulation process and granules properties.


DISCLAIMER

This presentation reflects the views of the presenter and should not be construed to represent FDA’s

views or policies.