(123b) Fitness for Service Assessment after Demethanizer Arbf Near Miss
AIChE Spring Meeting and Global Congress on Process Safety
2021
2021 AIChE Virtual Spring Meeting and 17th Global Congress on Process Safety
Topical 4: The 33rd Ethylene Producers Conference
Ethylene Plant Safety I
Thursday, April 22, 2021 - 11:10am to 11:35am
On June 15th, 2018 at the LyondellBasell Channelview OP1 olefins unit, a process upset in the chilling train led to temperatures colder than the Minimum Design Metal Temperature (MDMT) of the T-3601 Demethanizer Tower. A Level 3 Brittle Fracture Fitness for Service (FFS) assessment was performed to establish minimum allowable temperature (MAT) acceptance criteria based on fracture mechanics (API 579 Part 9, Level 2 methodology) and subsequent crack inspections were performed to validate assessment results. This paper will demonstrate the steps required to perform a level 3 FFS assessment and will show how process modeling tools can be used to estimate dynamic temperature changes when direct measurement is not available. Additionally, the hazard scenario in context of the Process Hazard Analysis will be reviewed along with proposed safeguards.