(156a) It Was a Dark and Stormy Night – Investigation of Acrylate Storage Tank Explosions
AIChE Spring Meeting and Global Congress on Process Safety
2021
2021 AIChE Virtual Spring Meeting and 17th Global Congress on Process Safety
Global Congress on Process Safety
GCPS Joint Session: Case Histories I
Friday, April 23, 2021 - 9:30am to 9:50am
It was in the early morning hours of May 16, 2012 when a thunderstorm rolled into the Bristol, Pennsylvania plant where The Dow Chemical Company produced acrylic polymers. As the weather turned stormy, lightning struck in the tank farm area containing inhibited ethyl acrylate, butyl acrylate, and methyl methacrylate. Within seconds, an ethyl acrylate tank exploded and was followed a few minutes later by a butyl acrylate tank explosion. The explosions and ensuing fire damaged the tank farm and led to a lengthy shutdown; fortunately, there were no injuries. This paper details the investigation into the complex sequence of events that led to the two explosions. The investigation team evaluated data gathered from eyewitnesses, security system cameras, weather services, and the process control system. The team also analyzed physical evidence including electrical bonding and grounding systems, deflagration arresters, and various tank components. Although the adjacent ethyl and butyl acrylate tanks were involved in the event, the investigation did find that flame isolation devices functioned as intended and prevented the propagation of flames to surrounding processes via the interconnected venting system. However, there was a puzzle left to unravel. The tank installations were determined to be in compliance with the industry lightning standards NFPA 780, NFPA 545, and API 2003. If the tanks met industry standards, how did the explosion happen? While the exact mechanism could not be determined with certainty, the ignition of the atmosphere in the ethyl acrylate tank most likely occurred from a spark discharge inside the tankâs headspace, likely between internal components at different electrical voltage potentials. This type of mechanism could invalidate the Faraday Cage assumption inherent in current industry guidance and may represent a hazard that is not currently well-recognized in industry. It should also be noted that, while lightning canât be prevented, the outcome of a lightning strike can also be mitigated by the use of safeguards such as inertion, flame arresters, diking, and foam systems.
Checkout
This paper has an Extended Abstract file available; you must purchase the conference proceedings to access it.
Do you already own this?
Log In for instructions on accessing this content.
Pricing
Individuals
AIChE Pro Members | $150.00 |
AIChE Emeritus Members | $105.00 |
Employees of CCPS Member Companies | $150.00 |
AIChE Graduate Student Members | Free |
AIChE Undergraduate Student Members | Free |
AIChE Explorer Members | $225.00 |
Non-Members | $225.00 |