(296a) Back Extraction of Pna Affinity Tags Following Hic Purification of DNA Targets
AIChE Annual Meeting
2005
2005 Annual Meeting
Bioseparations
Advances in Bioseparations I (co-spon. 5 and 15c)
Wednesday, November 2, 2005 - 8:00am to 8:20am
Conventional nucleic acid purification techniques rely on differences in size, shape, and charge density to separate target samples from heterogeneous mixtures. However, the non-specific nature of these processes does not allow for separation of nucleic acid strands of comparable size but different sequence. This is a critical concern for a variety of applications; for example, to ensure sequence homology in plasmids used for gene therapy, for PCR-based amplification of low copy-number targets, and for extraction of trace mRNAs for expression analysis. While sequence-specific affinity tags have been used for DNA purification, they are typically immobilized on solid supports, thereby inhibiting recovery yields by slow DNA binding kinetics and non-specific surface fouling. These difficulties may be alleviated with the use of soluble, self-assembling affinity tags.
Previous work in our group has shown that PNAA can bind target ssDNA and dsDNA, and using hydrophobic interaction chromatography (HIC), these complexes can be separated from non-target strands. Like most existing nucleic acid purification techniques, separation of similarly-sized strands is impossible in traditional HIC. The affinity tag selectively alters the hydrophobicity, and hence the retention, of the resulting complex, providing a large shift in retention volume for target sequences compared to unlabeled DNA. As an extension of this work, we have demonstrated that target ssDNA and dsDNA can be separated from heterogeneous DNA mixtures. By careful manipulation of common HIC parameters, we have achieved high-resolution separation of a 60-base target ssDNA and a 40bp dsDNA oligomer from non-target DNA with single base mismatch sensitivity. However, PNAA binds dsDNA with high affinity, making PNAA removal under non-DNA denaturing conditions exceedingly difficult. The removal, or back-extraction, of the PNAA affinity tag is critical before performing PCR amplification of HIC products, or using HIC products for gene therapy.
Recently, we have discovered that the PNAA affinity tag can be removed from a sub-population of PNAA/dsDNA complexes using centrifugally-driven size exclusion, and that this enriched sample can undergo PCR amplification without complication. HIC fractions were collected and subjected to centrifugation at 12,000g in Microcon (Millipore, Billerica, MA) spin filters at room temperature. Subsequent PAGE analysis illustrated the reappearance of intact target DNA, devoid of affinity tag, along with two distinct PNAA-DNA complex stoichiometries, one of which dynamically forms during HIC. These stoichiometries were identified using MALDI-TOF mass spectrometry and electrophoresis. By adding non-target strands with a molecular weight distinct from target prior to HIC, we have also shown that DNA capture and subsequent removal is sequence-specific, as no non-target DNA, free or PNAA-bound, appears in the gel. It is believed that a combination of centrifugal heating and mechanical shearing is responsible for PNAA removal and potential scale-up using available industrial techniques will be discussed.
Checkout
This paper has an Extended Abstract file available; you must purchase the conference proceedings to access it.
Do you already own this?
Log In for instructions on accessing this content.
Pricing
Individuals
AIChE Pro Members | $150.00 |
AIChE Graduate Student Members | Free |
AIChE Undergraduate Student Members | Free |
AIChE Explorer Members | $225.00 |
Non-Members | $225.00 |