(234g) Capillary Waves at the Liquid-Vapor Interface and the Surface | AIChE

(234g) Capillary Waves at the Liquid-Vapor Interface and the Surface

Authors 

Ismail, A. E. - Presenter, Sandia National Laboratories
Stevens, M. J. - Presenter, Sandia National Laboratories


Capillary waves occurring at the liquid-vapor interface of water are studied using molecular dynamics simulations. In addition, the surface tension, determined thermodynamically from the di¤erence in the normal and tangential pressure at the liquid-vapor interface, is compared for a number of standard three- and four-point water models. We study four three-point models (SPC/E, TIP3P, TIP3P-CHARMM, and TIP3P-Ew) and two four-point models (TIP4P and TIP4P-Ew). All of the models examined underestimate the surface tension; the TIP4P-Ew model comes closest to reproducing the experimental data. The surface tension can also be determined from the am- plitude of capillary waves at the liquid-vapor interface by varying the surface area of the interface. The surface tensions determined from the amplitude of the logarithmic divergence of the capillary interfacial width and from the traditional thermodynamic method agree only if the density profile is fitted to an error function instead of the usually-assumed hyperbolic tangent function.