(551d) Experimental Verification of Hydrodynamic Multiplicity in an Industrial Trickle Bed Reactor | AIChE

(551d) Experimental Verification of Hydrodynamic Multiplicity in an Industrial Trickle Bed Reactor

Authors 

Van der Merwe, W. - Presenter, University of Pretoria
van Houwelingen, A. J. - Presenter, University of Pretoria
Nicol, W. - Presenter, University of Pretoria


Trickle bed hydrodynamics has undergone intensive investigation in the last 5 decades. Parameters like pressure drop, liquid holdup and wetting efficiency directly impact the design (size, catalyst loading), operation (operating cost, thermal stability, catalyst utilization and catalyst life) and optimization of trickle bed reactors (TBR). The greatest drawback of data and correlations available in the open literature is the fact that the hydrodynamic parameters were determined almost exclusively on laboratory and pilot scale apparatus. In addition, the systems used in the studies were generally far removed from those encountered in industrial practice. As such, low pressure air with water as liquid phase together with glass beads as packing are often employed. Hysteresis in the hydrodynamic parameters was first reported by Kan & Greenfield (1979) and subsequently studied experimentally by Levec et al. (1986), Christensen et al. (1986), Lazzaroni et al. (1988), Lutran et al. (1991), Wang et al. (1995), Ravindra et al. (1997), Sederman & Gladden (2001) and Van der Merwe & Nicol (2005). All of these studies were laboratory scale, operated at low pressures and employed air, glass and water (sometimes doped with surfactants). It was observed that pressure drop varied by as much as 700 % depending on the exact history of gas and liquid flows, as well as the prewetting procedure employed. There are broadly classified pressure drop regions: an upper branch of the hystersis loop for beds that were subjected to high gas and/or liquid flow rates in their past, and a lower branch of the hysteresis loop for beds that either had not been prewetted or had drained (as a result of liquid flow interruption). The upper region is dominated by uniform flow (films spread evenly over all of the available surface). The lower region is dominated by non-uniform flow (localized rivulet or channelling flow). They are denoted as the Kan mode (high fluid rates in the past) and the Levec mode (post-draining operation) respectively. There are several strong arguments supporting the notion that hydrodynamic multiplicity is unlikely to exist in industrial reactors: (1) The surface tension of petrochemical liquids at high temperatures is typically seven times lower than that of water. The low surface tension is expected to allow the liquid to spread over the packing ? resulting in uniform film flow regardless of the flow history. (2) The contact angle between glass and water is much larger than the zero angle between liquids and porous catalsyts. Levec et al. (1986) in fact attributed their hysteresis observations to the difference between advancing and receding contact angles ? a difference that does not exist if the contact angle is zero. (3) The high pressures encountered in industry is expected to cause the gas to smear the liquid over the solid, thereby increasing the flow uniformity. (4) Intermittent shut-downs (trips) cause the bed to be properly wetted eventually since the liquid is believed to take a different path each time it is reintroduced. (5) If the liquid rivulets change path stochastically over long periods of time it will cause the bed to be properly wetted and the liquid to be uniformly distributed after several days of operation. In this work, an industrial trickle bed reactor is investigated during regular operation in a large petrochemical refinery. It is perfectly suited to an investigation into industrial hydrodynamic multiplicity. It is a typical industrial reactor according to points 1 to 4 listed above (petrochemical-hydrogen system, operating pressure 4 MPa, 3 mm commercial extrudate catalyst). It is operated at low gas (0.004 - 0.011 kg/m2s) and liquid (0.74 ? 1.22 kg/m2s) mass fluxes. This ensures operation in the trickle flow regime (as apposed to the high interaction regimes where hysteresis does not exist). There is a single bed and no intermediate liquid or gas feeds. The reactor operates nearly isothermally. The catalyst cokes very slowly. An electronic log of historic data going back several years is available for liquid and gas flow rates and pressure drop. Figure 1 is an excerpt of such historic data. It shows liquid flow rate and pressure drop for constant gas flow rate before and after a liquid interruption. Note that the liquid flow rate is very stable but there are periodic interruptions and rate variations. The gas flow rate exhibits considerable noise, but whenever the liquid rate is constant, the average gas flow rate usually remains relatively constant as well. The pressure drop also has a noise component that is attributable to the noise in the gas flow rate. In figure 1, the pressure drop directly after the reintroduction of liquid is lower than directly before the interruption. The liquid rate, gas rate, coking condition and other system parameters were identical for these two points. The only difference is that the bed had been subjected to a high liquid flow rate some time before the interruption (marked Lmax on figure 1), after which the liquid flow rate was reduced to the lower value that is encountered at the points at which we measure the pressure drop (marked L1). This analysis was repeated for several instances where the bed had fortuitously been subjected to a high liquid rate (L=Lmax), followed by a reduction to a lower rate (L=L1), followed by an interruption (L=0) and then a reintroduction at the previous rate (L=L1). Figure 2 shows that after a liquid feed interruption - reintroduction event the pressure drop is lower. This is understood easily in terms of the laboratory scale experiments. Upon liquid interruption, the liquid drains under gravity. When the liquid is re-introduced, the reactor is operated in the Levec mode. An increase in the liquid rate improves liquid spreading. Upon a subsequent decrease, the pressure drop is higher because the bed had moved toward more uniform operation. The pressure drop loop is shown qualitatively in figure 1 insert. This study constitutes the first experimental evidence of hydrodynamic hysteresis in an industrial trickle bed reactor during regular operation. Since nearly all pressure drop correlations do not take hystereis into account, there is a need to investigate the implications that multiple hydrodynamic states have on reactor performance. References Christensen, G., McGovern, S.J. and Sundaresan, S. (1986) A.I.Ch.E. J., 32, 1677. Kan, K.M. and Greenfield, P.F. (1979) Ind. Eng. Chem. Process Des. Dev., 18, 740. Lazzaroni, C.L., Keselman, H.R. and Figoli, N.S. (1988) Ind. Eng. Chem. Res., 27, 1132. Levec, J., Saez, A.E. and Carbonell, R.G. (1986) A.I.Ch.E. J., 32, 369. Lutran, P.G., Ng, K.M. and Delikat, E.P. (1991) Ind. Eng. Chem. Res., 30, 1270. Ravindra, P.V., Rao, D.P. and Rao, M.S. (1997) Ind. Eng. Chem. Res., 36, 5133. Sederman, A.J. and Gladden, L.F. (2001) Chem. Eng. Sci., 56, 2615. Van der Merwe, W. and Nicol, W. (2005) Ind. Eng. Chem. Res., 44, 9446. Wang, R., Mao, Z. and Chen, J. (1995) Chem. Eng. Sci., 50, 2321.

Checkout

This paper has an Extended Abstract file available; you must purchase the conference proceedings to access it.

Checkout

Do you already own this?

Pricing

Individuals

AIChE Pro Members $150.00
AIChE Graduate Student Members Free
AIChE Undergraduate Student Members Free
AIChE Explorer Members $225.00
Non-Members $225.00