(445f) Imaging Pharmaceutical Fluidised Bed Multi-Processes with Electrical Capacitance Tomography
AIChE Annual Meeting
2010
2010 Annual Meeting
Comprehensive Quality by Design in Pharmaceutical Development and Manufacture
Applications of Multivariate Data Analysis in Pharmaceutical Process Development
Wednesday, November 10, 2010 - 2:30pm to 2:50pm
The fluidised bed process (drying, granulation and coating) is an important procedure in pharmaceutical industry and the end point of product quality is strongly depended on the properly setting of operation parameters. However, due to the complex gas-solid two phases flow behavior in these processes and fast flow velocity, it is difficult to monitor and measure the process characteristics using conventional tools, such as pressure and optical fiber sensors. For a multi-phase flow process, a non-intrusive imaging methodology provides a useful tool for process monitoring and fault diagnosis. Compared with other process tomography techniques and considering non-conductive material in the pharmaceutical industry, ECT is the most suitable imaging technique for measuring fluidised bed multi-processes because it is fast (>100 frames per second) and can reconstruct a permittivity distribution as well as solid moisture content. The aim of this research is to investigate the behaviour of drying and granulation process in a fluidised bed by ECT with and without wurster tube, which can provide online monitoring and fault diagnosis and possibly provide a new approach to process control. To achieve such objective, an ECT sensor with 8 electrodes was used to monitor the fluidised bed process with different operation parameters. Key process parameters including cross-sectional area solid concentration, time averaged process raw capacitance signals, averaged solids concentration in the chamber, the effect of wurster tube on hydrodynamic behavior and the domain frequency spectrum distribution in the chamber were analyzed. Experiment results indicate that process moisture change can be addressed from the raw capacitance of adjacent electrode pair combined with calibration model. The results show that ECT technology can be used in pharmaceutical fluidised bed process and future work is given in the end of this paper.
Topics
Checkout
This paper has an Extended Abstract file available; you must purchase the conference proceedings to access it.
Do you already own this?
Log In for instructions on accessing this content.
Pricing
Individuals
2010 Annual Meeting
AIChE Pro Members | $150.00 |
AIChE Graduate Student Members | Free |
AIChE Undergraduate Student Members | Free |
AIChE Explorer Members | $225.00 |
Non-Members | $225.00 |
Comprehensive Quality by Design in Pharmaceutical Development and Manufacture only
AIChE Pro Members | $100.00 |
Food, Pharmaceutical & Bioengineering Division Members | Free |
AIChE Graduate Student Members | Free |
AIChE Undergraduate Student Members | Free |
AIChE Explorer Members | $150.00 |
Non-Members | $150.00 |