(323e) Automated Selective Cell Manipulation Using Dielectrophoresis
AIChE Annual Meeting
2017
2017 Annual Meeting
2017 Annual Meeting of the AES Electrophoresis Society
Electrokinetics for Biological Separation and Analysis
Tuesday, October 31, 2017 - 10:00am to 10:15am
Automated Selective Cell manipulation
using Dielectrophoresis
Rucha Natu, Monsur Islam, Rodrigo Martinez Duarte
Department of Mechanical Engineering,
Clemson,SC
Here we present a novel technique for automated cell
manipulation using a dielectrophoretic chip with
motion activation using a 3d printer. Dielectrophoresis
is widely used for selective cell manipulation and trapping. Due to its ability
for rapid, label free cell sorting at a high efficiency, dielctrophoresis
is a promising technique for sample preparation. Use of 3D electrodes has
enhanced the region for action of DEP field and shows a capability of obtaining
high throughput. The technique developed by our group uses the advantage of 3D
carbon electrodes as a first step towards sample preparation. A 3D carbon
electrode DEP chip is used to trap and transfer selected cells to the process
plate. The final objective is to integrate cell separation and lysis on the
automated chip to obtain the intra cellular material for sample processing.
A 3D carbon electrode chip, fabricated by
SU8-Photolithography, as detailed by our group previously, [1] is used for this
experiment. The chip is mounted on a 3D printer facing the printer platform.
The 3d printer is programmed using G-code to control the motion of the chip. The
setup is shown in Figure 1a. The chip is first immersed in the cell culture
plate, which contains a mixture of cells and particles. A mixture of 10um latex
particles and Candida albicans
is used for this process. At 200 kHz, and 20Vpp, Candida albicans are trapped by positive dielectrophoresis whereas the latex particles are not
trapped. The chip with the trapped cells is raised from the culture by the 3D
printer and is transferred to the wash plate. As, the chip is raised out of the
culture plate, the media wets the chip. Some cells and 10um particles remain
suspended in the media and get carried along with the chip. In the wash plate,
the untrapped cells and the latex particles, acquired
due to wetting of the chip are removed. Since the electric field remains ON
during this step, the candida albicans remain trapped. In the next step, the chip is
immersed in the sample plate, where the field is switched OFF. In the absence
of the DEP force, the candida cells are released in the sample plate. The
process is shown in details in the schematic in Figure 1b. The cells retrieved
in the sample plate with DEP and without DEP were counted to determine the
concentration of the cells obtained in sample plate. When DEP field is off, the cells get transferred
as the water wets the electrode surface. The graph in Figure 1c, shows the
difference in the concentration of cells obtained in the sample plate in both
cases. The higher concentration in the case of DEP proves that DEP can be used
to effectively transfer selected cells.
Current work is to develop the process to completely eliminate
the cell transfer due to wetting. The number of cells transferred are being
characterized as a function of applied voltage and the concentration of cell
culture. The final objective is to develop the device for sample preparation,
where with the increase of voltage in the chip and thus the resulting electric
field, the cells can be lysed. The intra cellular material after cell lysis can
be deposited at the sample site directly. Use
of 3D printer can enable control of the chip motion and hence the cells or
intra cellular material can be dropped at specific locations automatically.
Figure 1a) The 3d
printer set up with the DEP chip mounted on the holder is shown in the figure. b)The schematic of the cell transfer device shows steps
involved in picking and transferring the cells from culture to sample plate c) The
plot of log of cell concentration obtained after each cycle is shown in this
graph. Number of cells obtained in every cycle with DEP are more than the
number of cells obtained in the cycles without DEP. This indicates that the DEP
chip can be used to transfer