(95c) The Influence of Hydrophilic Properties on Foamy Three Phase Systems
AIChE Spring Meeting and Global Congress on Process Safety
2013
2013 Spring Meeting & 9th Global Congress on Process Safety
Global Congress on Process Safety
Overpressure Control Methods and Alternatives II
Tuesday, April 30, 2013 - 4:30pm to 5:00pm
In different industrial fields amphiphile components are used. These components potentially lead to the formation of foams. Normally those foams are not desired and are usually avoided. But in setups like a bubble column or during flash evaporation it is not uncommon that limitations are reached.
Another field where foam formation leads to drastic problems is in the case of venting. The venting of foamy systems has been widely researched for several centuries. Nevertheless, still only conservative assumptions can be made to determine the needed safety valve or rupture disc size needed for a given scenario.
If a third phase consisting of solid particles, like catalysts, is additionally included in the system even experimental data is scarce. Up to date those scenarios have not sufficiently been taken into account.
In this work an experimental investigation on the influence of particles on foaming systems is presented by comparing foaming two-phase and three-phase systems and non-foaming three-phase systems .
Experiments were carried in two different setups differing in reactor volume, height-to-diameter ratio and material to study wall effects as well as influences of the particles on the bubble nucleation Silicabeads were used and compared in hydrophilic sodiumdodecylsulfate (SDS) and Falterol solutions. To determine the effect of surface forces the particles were used without any further preparation and also sylilated. The sylilated particles have are hydrophobic while the plain particles are hydrophilic.
Results show, that with plain particles an increase in mass discharge and a slower decrease in pressure are observed. Particles are not significantly vented. Aveyard et al [1] indicate that this results due to the stabilization of hydrophilic foams by hydrophilic particles.
For sylilated particles the effect is expected to be even more pronounced. The particles will float at the beginning of the experiment. But while particles floating due to their density show no effect on the venting process [2], the sylilated are expected to be discharged at the beginning of the depressurization and thus slow the pressure decrease. Results of first experiments proof this influence.
According to these results even conservative assumptions made during design of safety valves or rupture disks for foaming systems may lead to venting areas that are not sufficiently large and thus to unsafe conditions.
A recommendation on consideration of these effects for the design of safety valves or rupture discs will be given.
[1] Aveyard, S. et al., Measurement of contact angles of spherical monodisperse particles with surfactant solutions, Colloids and surfaces A, Elsevier Science B.V., 1994; 83, 89-98
[2] Poli, M., et al.; Venting of foaming three-phase systems, Chemical Engineering Technology, 2009, 32, 2, 312-318
Checkout
This paper has an Extended Abstract file available; you must purchase the conference proceedings to access it.
Do you already own this?
Log In for instructions on accessing this content.
Pricing
Individuals
AIChE Pro Members | $150.00 |
AIChE Graduate Student Members | Free |
AIChE Undergraduate Student Members | Free |
AIChE Explorer Members | $225.00 |
Non-Members | $225.00 |