(164b) Control Valve Packing Follower Failure
AIChE Spring Meeting and Global Congress on Process Safety
2016
2016 AIChE Spring Meeting and 12th Global Congress on Process Safety
The 28th Ethylene Producers’ Conference
Ethylene Unit Safety Session
Wednesday, April 13, 2016 - 8:30am to 8:55am
The authors will detail the incident of a control valve packing follower failure in cold service. While attempting a repair, the follower failed on a process service @ 465 psig / -150 degrees Fahrenheit which was eminent based on an operations / maintenance action. The failure potential of failing without any interaction was highly possible due to the broken follower.
Some of the topics that will be covered by the authors are:
1. The root cause analysis findings from the incident.
2. The immediate corrective actions taken as a result of the findings.
3. The long term corrective action items and the path forward to implement them.