(180c) Gasoline Sulfur Reduction in FCC Using Catalyst Additives
AIChE Spring Meeting and Global Congress on Process Safety
2016
2016 AIChE Spring Meeting and 12th Global Congress on Process Safety
19th Topical Conference on Refinery Processing
Advances in Catalysis
Wednesday, April 13, 2016 - 2:30pm to 3:00pm
Reducing sulfur in the naphtha cut off an FCC is an important consideration since 90% of the naphtha sulfur in a given refinery typically comes from FCC naphtha. The amount of reducible sulfur depends on whether or not the FCC feed is hydrotreated. With hydrotreated feed, the sulfur in the gasoline cut is typically lower, but the sulfur that remains is more difficult to remove (aromatic sulfur). On the other hand, unhydrotreated feed contains higher sulfur but is easier to remove. Saturates, mercaptans, thiophenes, and alkyl thiophenes see good or reasonable conversion to H2S or coke with the use of an additive. Benzothiophenes, although present in lower quantities than other species, have much lower conversion rates and are harder to remove. A sulfur reduction from benzothiophene of 15% or less is common with an additive.
Overall, when looking at the entire sulfur species in FCC naphtha, an average of about 20-40% reduction across the entire boiling point range can be achieved with gasoline sulfur reduction additives. Typical loading is about 15-25% of the base catalyst and can be synergistically combined with the base catalyst formulation to minimize activity loss via dilution effects. This presentation will discuss recent testing with gasoline sulfur reduction additives and FCC unit examples.