(57bu) The Study of Safety Evaluation Technique for High Temperature Process
AIChE Spring Meeting and Global Congress on Process Safety
2017
2017 Spring Meeting and 13th Global Congress on Process Safety
Global Congress on Process Safety
GCPS Poster Session
Monday, March 27, 2017 - 5:00pm to 7:00pm
These troubles are caused by the thermal decomposition by a sudden temperature rise. The temperature program of the analytical instrument which is generally used by a thermal analysis is 10-20â /min. The conventional thermal analysis equipment cannot evaluate the temperature rise rate at the time of the trouble exactly to become than 20â/min. It becomes the problem that the slow temperature rise may be different from rapid heating up in a decomposing reaction.
We produced a device capable of quickly raising temperature to solve these problems.
This device is comprised of the vertical plumbing which it sealed and heating furnace, and it is very simple structure. The sample holder is fixed to the upper part in the plumbing by a magnet. And the holder drops in the heating zone by keeping a magnet away from the plumbing and is heated rapidly. The materials of the plumbing are SUS316L, and, as for the use upper limit temperature, 500â, the use upper limit pressure are 1MPa. Because the deterioration of SUS materials by the heat is intense when it is raised the temperature of the device to 750â, the plumbing is disposable.
The inside of the plumbing is replaced with inert gases such as nitrogen, argon. The maximum temperature rising rate is 150â/min (furnace temperature: 750â).
We introduce an example of the trouble analysis of a firing furnace and kneading machine using this device.
[Case example 1] Study of firing furnace trouble
After burning with a new additive at 720â,ãabnormal pressure rise happened in a furnace, and a plant stopped. After measuring quantity of outbreak gas using the rapid heating device, it was recognized that gas of 7 times was generated and a gasification rate tripled in comparison with a conventional additive.
[Case example 2] Study of kneading machine trouble by overheating
The additive which had low heat stability was spent mistakenly in large quantities to a kneading machine, and a vent board exploded. After performing a rapid temperature rise examination under a kneading temperature condition, as for the pressure raising rate when an additive disintegrated, 1.8MPa/min, the quantity of gasification became 190L/kg. The additive concentration became (mixing ratio with the resin) more than at least 75%, and it was recognized that a large amount of additives were invested mistakenly.
Fortunately, this example does not become the big accident with resulting in injury or death. In this explosion example, a vent board penetrated a checker plate. It might become the casualty when there was a person near a kneading machine.
In comparison with the plant of the petrochemical and fine chemistry that heat risk analytical technique establishes, the firing furnace and kneading machine is often run without detailed risk assessment. The rapid heating device becomes the powerful tool to do the heat risk evaluation of these high temperature processes.
In future, it is going to be improved the rapid heating device changes the plumbing materials, and to use it to the temperature ranges more than 1,000â.